| MWI(0) | 90 | kDa | 
| MWexpected | 62 | kDa | 
| VPorod | 145 | nm3 | 
| 
				 
					log I(s)
					
						2.36×103
						2.36×102
						2.36×101
						2.36×100
					
				 
			 | 
			
				 
					
						 s, nm-1
					
				 | 
			
		    
 
  | 
	
	
				
 
 
  | 
	
                                
  | 
                            
                                
                                
                                
                                
                                    
					
		
			
		
			
			
			 
			
			
			 | 
			
                                
  | 
                            
                                
                                
                                
                                
                                    
					
		
			
		
			
			
			 
			
			
			 | 
			
| 
				
					
	
		Synchrotron SAXS data from solutions of uncharacterized protein CTHT_0072540 (Core) from Chaetomium thermophilum in 20 mM HEPES, 100 mM NaCl, 2 mM β-mercaptoethanol, pH 7.5, were collected on the P12 beam line at the PETRAIII the storage ring (Hamburg, Germany) using a Pilatus 2M detector at a sample-detector distance of 3.1 m and at a wavelength of λ = 0.124 nm (I(s) vs s, where s = 4πsinθ/λ and 2θ is the scattering angle). Solute concentrations ranging between 1.3 and 5 mg/ml were measured at 25°C. 20 successive 1 second frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted and the different curves were scaled for protein concentration.
		 Storage temperature = UNKNOWN  | 
				
						
		
  | 
			|||||||||||||||||||||||||||