Gold Nanoparticle X‐ray Scattering to Detect Small Molecule Effectors of Enzyme‐DNA Allostery

Del Mundo J Rosenberg D, Kim L, Gora N, Moiani D, Jones D, Langelier M, Pascal J, Tainer J, Hura G, Small Methods (2026) DOI

SASDX85 – poly(ADP-ribose) polymerase 1 (PARP1) free in solution

Poly [ADP-ribose] polymerase 1
MWexperimental 119 kDa
MWexpected 113 kDa
VPorod 280 nm3
log I(s) 5.50×101 5.50×100 5.50×10-1 5.50×10-2
Poly [ADP-ribose] polymerase 1 small angle scattering data  s, nm-1
ln I(s)
Poly [ADP-ribose] polymerase 1 Guinier plot ln 5.51×101 Rg: 4.6 nm 0 (4.6 nm)-2 s2
(sRg)2I(s)/I(0)
Poly [ADP-ribose] polymerase 1 Kratky plot 1.104 0 √3 sRg
p(r)
Poly [ADP-ribose] polymerase 1 pair distance distribution function Rg: 5.0 nm 0 Dmax: 20.4 nm

Data validation


Fits and models


log I(s)
 s, nm-1
Poly [ADP-ribose] polymerase 1 BILBOMD model

Synchrotron SAXS data from solutions of poly(ADP-ribose) polymerase 1 (PARP1) free in solution in 12 mM HEPES, 60 mM KCl, 8 mM MgCl2, 4% glycerol, 5.7 mM beta-mercaptoethanol, pH 8 were collected on the 12.3.1 (SIBYLS) beam line at the Advanced Light Source (ALS) storage ring (Berkeley, CA, USA) using a Pilatus3 X 2M detector at a sample-detector distance of 2.1 m and at a wavelength of λ = 1.23984 nm (I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). Solute concentrations ranging between 0.4 and 3 mg/ml were measured at 20°C. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted. The low angle data collected at lower concentrations were extrapolated to infinite dilution and merged with the higher concentration data to yield the final composite scattering curve.

X-ray Exposure time = UNKNOWN. Number of frames = UNKNOWN

Poly [ADP-ribose] polymerase 1 (PARP1)
Mol. type   Protein
Organism   Homo sapiens
Olig. state   Monomer
Mon. MW   113.1 kDa
 
UniProt   P09874
Sequence   FASTA