Synchrotron SAXS
data from solutions of
poly(ADP-ribose) polymerase 1 (PARP1) free in solution
in
12 mM HEPES, 60 mM KCl, 8 mM MgCl2, 4% glycerol, 5.7 mM beta-mercaptoethanol, pH 8
were collected
on the
12.3.1 (SIBYLS) beam line
at the Advanced Light Source (ALS) storage ring
(Berkeley, CA, USA)
using a Pilatus3 X 2M detector
at a sample-detector distance of 2.1 m and
at a wavelength of λ = 1.23984 nm
(I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle).
Solute concentrations ranging between 0.4 and 3 mg/ml were measured
at 20°C.
The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.
The low angle data collected at lower concentrations were extrapolated to infinite dilution and merged with the higher concentration data to yield the final composite scattering curve.
X-ray Exposure time = UNKNOWN. Number of frames = UNKNOWN
|
|