Synchrotron SAXS
data from solutions of
NADPH bound Clostridium leptum carboxyaminopropylagmatine dehydrogenase
in
50 mM Tris, 300 mM NaCl, 10% glycerol, 1 mM DTT, pH 8
were collected
on the
BL4-2 beam line
at the Stanford Synchrotron Radiation Lightsource (SSRL) storage ring
(Menlo Park, CA, USA)
using a Rayonix MX225-HE detector
at a sample-detector distance of 1.7 m and
at a wavelength of λ = 0.1128 nm
(I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle).
Solute concentrations ranging between 0.3 and 4.5 mg/ml were measured
at 22°C.
10 successive
1 second frames were collected.
The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.
The low angle data collected at lower concentration were merged with the highest concentration high angle data to yield the final composite scattering curve.