Galien A,
Hutin S,
Le Hir S,
Paul M,
Albanese P,
Kieffer-Jaquinod S,
Guillotin A,
Iwabuchi N,
Maejima K,
Nanao MH,
Tully MD
Hugouvieux V,
Zubieta C,
J Biol Chem
302(10):113449
(2026)
Europe PMC
Synchrotron SAXS
data from solutions of
MADS transcription factor SEPALLATA 3 (SEP3)
in
50 mM Tris, 300 mM NaCl, 1 mM TCEP, pH 8
were collected
on the
B21 beam line
at the Diamond Light Source storage ring
(Didcot, UK)
using a Eiger 4M detector
at a sample-detector distance of 3.7 m and
at a wavelength of λ = 0.1 nm
(I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle).
One solute concentration of 11.30 mg/ml was measured
at 20°C.
620 successive
1 second frames were collected.
The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.