			Synchrotron SAXS 
		
        data from solutions of
        Human Albumin (C6) control  SIGMA
		
		    in 
			20 mM Tris, 150 mM KCl, 2% glycerol, pH 7.4
		
 		were collected
		
		on the
		
			12.3.1 (SIBYLS) beam line  
		
		
			at the Advanced Light Source (ALS) storage ring
		
		
			(Berkeley, CA, USA)
		
		
		
			using a Pilatus3 X 2M detector
		
		
			at a sample-detector distance of 2.1 m and
		
		
			at a wavelength of λ = 0.1127 nm
		
		(I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle).
                
                In-line size-exclusion chromatography (SEC) SAS was employed. The SEC parameters were as follows: A 55.00 μl sample
                at 3 mg/ml  was injected at a 0.50 ml/min flow rate
                onto a  Shodex LW-803  column
		
                        at 20°C.
		
			600 successive
			
				3 second frames were collected.
			
		
			The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.
		
		 
            
                
		    
		 
	
				
					
				 | 
				
						
		
				
					
						| 
							
								Albumin
							
							
						 | 
					 
					
					
						| Mol. type | 
						  | 
						Protein | 
					 	
					
					
					
						| Organism | 
						  | 
						Homo sapiens | 
					 
					
					
					
						| Olig. state | 
						  | 
						
							Monomer | 
						
					 
					
					
					
						| Mon. MW | 
						  | 
						69.4 kDa | 
					 
					
					
						
							|   | 
						 
						
							| UniProt | 
							  | 
							
								P02768
									
								
							 | 
						 
						
					
						
							
								| Sequence | 
								  | 
								FASTA | 
							
						 
						
							|   | 
						 
					
				
	
	
	
	
		
					
		
	
		 
				 |