			Synchrotron SAXS 
		
        data from solutions of
        Segment S(110-125) of the Neurofilament low intrinsically disordered tail domain
		
		    in 
			20 mM Tris, 3 M GdnHCl, pH 8
		
 		were collected
		
		on the
		
			EMBL P12 beam line  
		
		
			at the PETRA III storage ring
		
		
			(DESY; Hamburg, Germany)
		
		
		
			using a Pilatus 6M detector
		
		
			at a sample-detector distance of 3 m and
		
		
			at a wavelength of λ = 0.124 nm
		
		(I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle).
                
			One solute concentration of 4.00 mg/ml was measured
                        at 10°C.
		
			The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.
		
		 
            
                Number of frames = UNKNOWN
		    
		 
	
				
					
				 | 
				
						
		
				 |